{"id":3691,"date":"2026-01-06T20:07:17","date_gmt":"2026-01-06T19:07:17","guid":{"rendered":"https:\/\/contec-ias.com\/case\/modernizacja-podstacji-wn-sn-w-rafinerii-ropy-naftowej\/"},"modified":"2026-04-28T12:22:14","modified_gmt":"2026-04-28T11:22:14","slug":"modernizacja-podstacji-wn-sn-w-rafinerii-ropy-naftowej","status":"publish","type":"case","link":"https:\/\/contec-ias.com\/pl\/przypadek\/modernizacja-podstacji-wn-sn-w-rafinerii-ropy-naftowej\/","title":{"rendered":"Modernizacja podstacji WN\/SN w rafinerii ropy naftowej"},"content":{"rendered":"\n<section  class=\"we-usps\" data-aos=\"fade\">\n    <div class=\"inner-content\">\n                        <div class=\"usps-container\">\n                                    <div class=\"usp-item\" data-aos=\"fade-up\">\n                <div class=\"content\">\n                    <h3>Wymiana przestarza\u0142ych system\u00f3w \u015bredniego napi\u0119cia w celu zapewnienia bezpiecznej, ci\u0105g\u0142ej produkcji<\/h3>\n<p>Belgijski klient z sektora petrochemicznego skontaktowa\u0142 si\u0119 z nami z pro\u015bb\u0105 o wymian\u0119 mocno przestarza\u0142ej instalacji \u015bredniego napi\u0119cia. Ryzyko awarii i nieplanowanych przestoj\u00f3w ros\u0142o z dnia na dzie\u0144, a ich wymagania by\u0142y jasne: wymiana rozdzielnicy przy minimalnych zak\u0142\u00f3ceniach w pracy, zapewniona przez jasn\u0105 komunikacj\u0119 mi\u0119dzy wszystkimi zainteresowanymi stronami. <\/p>\n<p>Nasze rozwi\u0105zanie koncentrowa\u0142o si\u0119 na dostarczeniu bezpiecznego i niezawodnego systemu poprzez doskona\u0142o\u015b\u0107 in\u017cynieryjn\u0105 i \u015bcis\u0142\u0105 koordynacj\u0119 z klientem i wykonawcami.<\/p>\n                <\/div>\n                                <ul class=\"usps-list\">\n                                        <li class=\"usp-list-item\">\n                        <img decoding=\"async\" src=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/icon-electric.svg\" alt=\"\">\n                        <b class=\"usp-text\">\n                            Pe\u0142na inwentaryzacja istniej\u0105cej instalacji i tras kablowych                        <\/b>\n                    <\/li>\n                                        <li class=\"usp-list-item\">\n                        <img decoding=\"async\" src=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/icon-electric.svg\" alt=\"\">\n                        <b class=\"usp-text\">\n                            Badania przep\u0142ywu obci\u0105\u017cenia i zwarcia                        <\/b>\n                    <\/li>\n                                        <li class=\"usp-list-item\">\n                        <img decoding=\"async\" src=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/icon-electric.svg\" alt=\"\">\n                        <b class=\"usp-text\">\n                            Wyb\u00f3r specyfikacji i dostawc\u00f3w zgodnie z normami bezpiecze\u0144stwa i jako\u015bci petrochemicznej.                        <\/b>\n                    <\/li>\n                                        <li class=\"usp-list-item\">\n                        <img decoding=\"async\" src=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/icon-electric.svg\" alt=\"\">\n                        <b class=\"usp-text\">\n                            Szczeg\u00f3\u0142owy projekt elektryczny we wsp\u00f3\u0142pracy z klientem i dostawc\u0105                        <\/b>\n                    <\/li>\n                                        <li class=\"usp-list-item\">\n                        <img decoding=\"async\" src=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/icon-electric.svg\" alt=\"\">\n                        <b class=\"usp-text\">\n                            Rysunki konstrukcji elektrycznych, listy materia\u0142\u00f3w i kabli oraz instrukcje pracy ze zdj\u0119ciami                        <\/b>\n                    <\/li>\n                                        <li class=\"usp-list-item\">\n                        <img decoding=\"async\" src=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/icon-electric.svg\" alt=\"\">\n                        <b class=\"usp-text\">\n                            Integracja SCADA do monitorowania w czasie rzeczywistym i zdalnego sterowania                        <\/b>\n                    <\/li>\n                                        <li class=\"usp-list-item\">\n                        <img decoding=\"async\" src=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/icon-electric.svg\" alt=\"\">\n                        <b class=\"usp-text\">\n                            Etapowy plan realizacji z tymczasowymi obej\u015bciami w celu utrzymania produkcji                        <\/b>\n                    <\/li>\n                                        <li class=\"usp-list-item\">\n                        <img decoding=\"async\" src=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/icon-electric.svg\" alt=\"\">\n                        <b class=\"usp-text\">\n                            Rozbudowane testy FAT (fabryczny test akceptacyjny) i SAT (test akceptacyjny w miejscu instalacji)                        <\/b>\n                    <\/li>\n                                        <li class=\"usp-list-item\">\n                        <img decoding=\"async\" src=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/icon-electric.svg\" alt=\"\">\n                        <b class=\"usp-text\">\n                            Nadz\u00f3r budowlany i zarz\u0105dzanie odchyleniami                        <\/b>\n                    <\/li>\n                                        <li class=\"usp-list-item\">\n                        <img decoding=\"async\" src=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/icon-electric.svg\" alt=\"\">\n                        <b class=\"usp-text\">\n                            Terminowa dostawa nowego systemu MV bez niespodzianek                        <\/b>\n                    <\/li>\n                                    <\/ul>\n                            <\/div>\n                    <\/div>\n        <\/section>\n<section  class=\"we-image_content\">\n    <div class=\"inner-content right default content\">\n        <div class=\"content\" data-aos=\"fade-right\">\n            <p class=\"small-title\">\n                Wyzwanie            <\/p>\n            <div class=\"the-content\">\n                <h2><span style=\"font-weight: 400;\">Zapewnienie niezawodno\u015bci i bezpiecze\u0144stwa w dzia\u0142aj\u0105cym \u015brodowisku rafinerii ropy naftowej<\/span><\/h2>\n<p><span style=\"font-weight: 400;\">Przestarza\u0142a rozdzielnica \u015bredniego napi\u0119cia stwarza\u0142a rosn\u0105ce zagro\u017cenie dla bezpiecze\u0144stwa i czasu pracy. Wyzwaniem by\u0142a modernizacja systemu bez wstrzymywania produkcji, przy jednoczesnym zachowaniu zgodno\u015bci z surowymi normami technicznymi, bezpiecze\u0144stwa i jako\u015bci obowi\u0105zuj\u0105cymi w przemy\u015ble petrochemicznym.<br \/>\n<\/span><\/p>\n            <\/div>\n                    <\/div>\n        <div class=\"image-container\" data-aos=\"fade-left\">\n            <img decoding=\"async\" src=\"\" alt=\"\">\n        <\/div>\n    <\/div>\n<\/section>\n\n<section  class=\"we-slider_image\" data-aos=\"fade-up\">\n    <div class=\"inner-content\">\n                    <div class=\"images-wrapper\">\n                <div class=\"images-container\">\n                                            <div class=\"image-container\">\n                            <img decoding=\"async\" src=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/04\/Oil-Gas.png\" alt=\"oil &#038; gas\">\n                        <\/div>\n                                            <div class=\"image-container\">\n                            <img decoding=\"async\" src=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/04\/oil-and-gas.png\" alt=\"oil and gas\">\n                        <\/div>\n                                            <div class=\"image-container\">\n                            <img decoding=\"async\" src=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/11\/iso-article1.jpg\" alt=\"\">\n                        <\/div>\n                                            <div class=\"image-container\">\n                            <img decoding=\"async\" src=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/11\/iso-article3.jpg\" alt=\"\">\n                        <\/div>\n                                            <div class=\"image-container\">\n                            <img decoding=\"async\" src=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2026\/01\/oilgas-case-study2.jpg\" alt=\"\">\n                        <\/div>\n                                    <\/div>\n                <div class=\"arrows\">\n                    <button class=\"prev-arrow\">\n                        <svg width=\"14\" height=\"14\" viewBox=\"0 0 14 14\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\">\n                            <path\n                                d=\"M8.707 1.70703L7.293 0.29303L0.586001 7.00003L7.293 13.707L8.707 12.293L4.414 8.00003L14 8.00003L14 6.00003L4.414 6.00003L8.707 1.70703Z\"\n                                fill=\"currentColor\" \/>\n                        <\/svg>\n                    <\/button>\n                    <button class=\"next-arrow\">\n                        <svg width=\"14\" height=\"14\" viewBox=\"0 0 14 14\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\">\n                            <path\n                                d=\"M5.293 12.293L6.707 13.707L13.414 6.99997L6.707 0.292969L5.293 1.70697L9.586 5.99997H0V7.99997H9.586L5.293 12.293Z\"\n                                fill=\"currentColor\" \/>\n                        <\/svg>\n                    <\/button>\n                <\/div>\n            <\/div>\n            <\/div>\n<\/section>\n\n<section  class=\"we-content_columns\">\n    <div class=\"inner-content\">\n                    <p class=\"small-title\" data-aos=\"fade-up\">\n                Nasze podej\u015bcie            <\/p>\n                <div class=\"intro-container\" data-aos=\"fade-up\">\n            <h2><span style=\"font-weight: 400;\">Od przestarza\u0142ej infrastruktury do doskona\u0142o\u015bci operacyjnej<\/span><\/h2>\n        <\/div>\n        <div class=\"columns-container\">\n                            <div class=\"column\" data-aos=\"fade-up\" data-aos-delay=\"0\">\n                    <div class=\"the-content\">\n                        <p>Rozpocz\u0119li\u015bmy od kompleksowej analizy technicznej, w tym inwentaryzacji istniej\u0105cej instalacji, tras kablowych i bada\u0144 elektrycznych w celu wsparcia nowego projektu. Wsp\u00f3lnie z klientem wybrali\u015bmy dostawc\u0119, kt\u00f3ry spe\u0142ni\u0142 wszystkie kryteria techniczne, bezpiecze\u0144stwa i jako\u015bci. <\/p>\n<p>Aby przygotowa\u0107 projekt do realizacji, Contec:<\/p>\n<ul>\n<li>Dostarczono jasn\u0105 i praktyczn\u0105 dokumentacj\u0119 dla wykonawcy E&amp;I, w tym rysunki, listy materia\u0142\u00f3w i zdj\u0119cia.<\/li>\n<li>Opracowano etapowy plan wdro\u017cenia z obej\u015bciami w celu zapewnienia nieprzerwanej produkcji.<\/li>\n<li>Zintegrowanie nowej instalacji ze \u015brodowiskiem SCADA<\/li>\n<li>Przeprowadzono testy FAT i SAT w celu weryfikacji bezpiecze\u0144stwa, niezawodno\u015bci i funkcjonalno\u015bci.<\/li>\n<li>Zapewni\u0142 praktyczny nadz\u00f3r nad budow\u0105, identyfikuj\u0105c i rozwi\u0105zuj\u0105c odchylenia na miejscu w czasie rzeczywistym.<\/li>\n<\/ul>\n                    <\/div>\n                <\/div>\n                            <div class=\"column\" data-aos=\"fade-up\" data-aos-delay=\"50\">\n                    <div class=\"the-content\">\n                        <p><span style=\"font-family: Arial, sans-serif; text-align: justify;\">Dzi\u0119ki \u015bcis\u0142emu monitorowaniu i koordynacji, nowa instalacja \u015bredniego napi\u0119cia zosta\u0142a dostarczona zgodnie z harmonogramem i bez niespodzianek.<\/span><\/p>\n<p><span style=\"font-family: 'Arial',sans-serif;\">Dzi\u0119ki tej udanej modernizacji Contec udowadnia swoj\u0105 warto\u015b\u0107 jako partner w z\u0142o\u017conych projektach infrastruktury energetycznej. Nasza wiedza techniczna i rygorystyczne wykonanie zapewni\u0142y klientowi korzy\u015bci z bezpiecznej, niezawodnej i gotowej na przysz\u0142o\u015b\u0107 instalacji SN, gwarantuj\u0105cej ci\u0105g\u0142o\u015b\u0107 produkcji w przysz\u0142o\u015bci. <\/span><\/p>\n                    <\/div>\n                <\/div>\n                    <\/div>\n    <\/div>\n<\/section>\n\n<section  class=\"we-featured_services\">\n    <div class=\"inner-content\">\n        <div class=\"title-container the-content\" data-aos=\"fade-up\">\n            <h2><span style=\"font-weight: 400;\">Dowiedz si\u0119 wi\u0119cej o naszych us\u0142ugach<\/span><\/h2>\n        <\/div>\n                    <div class=\"services-container\">\n                                                        <div class=\"service-item\" data-aos=\"fade-up\" data-aos-delay=\"0\">\n                        <div class=\"top\">\n                            <h4>Zarz\u0105dzanie operacjami produkcyjnymi<\/h4>\n                        <\/div>\n                        <div class=\"bottom\">\n                            <div class=\"image-container\"><img decoding=\"async\" width=\"1000\" height=\"1500\" src=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/service-manufacturing-operations.jpg\" class=\"attachment-large size-large wp-post-image\" alt=\"\" srcset=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/service-manufacturing-operations.jpg 1000w, https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/service-manufacturing-operations-200x300.jpg 200w, https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/service-manufacturing-operations-768x1152.jpg 768w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/div>\n                            <div class=\"arrow\">\n                                <a href=\"https:\/\/contec-ias.com\/pl\/us\u0142uga\/zarzadzanie-operacjami-produkcyjnymi\/\">\n                                    <svg width=\"21\" height=\"22\" viewBox=\"0 0 21 22\" fill=\"none\"\n                                        xmlns=\"http:\/\/www.w3.org\/2000\/svg\">\n                                        <path\n                                            d=\"M7.9395 18.9395L10.0605 21.0605L20.121 11L10.0605 0.939453L7.9395 3.06045L14.379 9.49995H0V12.5H14.379L7.9395 18.9395Z\"\n                                            fill=\"currentColor\" \/>\n                                    <\/svg>\n                                <\/a>\n                            <\/div>\n                        <\/div>\n                        <a href=\"https:\/\/contec-ias.com\/pl\/us\u0142uga\/zarzadzanie-operacjami-produkcyjnymi\/\" class=\"full-link\"><\/a>\n                    <\/div>\n                                                        <div class=\"service-item\" data-aos=\"fade-up\" data-aos-delay=\"50\">\n                        <div class=\"top\">\n                            <h4>Kontrola produkcji<\/h4>\n                        <\/div>\n                        <div class=\"bottom\">\n                            <div class=\"image-container\"><img decoding=\"async\" width=\"1000\" height=\"1500\" src=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/service-manufacturing-control.jpg\" class=\"attachment-large size-large wp-post-image\" alt=\"\" srcset=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/service-manufacturing-control.jpg 1000w, https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/service-manufacturing-control-200x300.jpg 200w, https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/service-manufacturing-control-768x1152.jpg 768w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/div>\n                            <div class=\"arrow\">\n                                <a href=\"https:\/\/contec-ias.com\/pl\/us\u0142uga\/kontrola-produkcji\/\">\n                                    <svg width=\"21\" height=\"22\" viewBox=\"0 0 21 22\" fill=\"none\"\n                                        xmlns=\"http:\/\/www.w3.org\/2000\/svg\">\n                                        <path\n                                            d=\"M7.9395 18.9395L10.0605 21.0605L20.121 11L10.0605 0.939453L7.9395 3.06045L14.379 9.49995H0V12.5H14.379L7.9395 18.9395Z\"\n                                            fill=\"currentColor\" \/>\n                                    <\/svg>\n                                <\/a>\n                            <\/div>\n                        <\/div>\n                        <a href=\"https:\/\/contec-ias.com\/pl\/us\u0142uga\/kontrola-produkcji\/\" class=\"full-link\"><\/a>\n                    <\/div>\n                                                        <div class=\"service-item\" data-aos=\"fade-up\" data-aos-delay=\"100\">\n                        <div class=\"top\">\n                            <h4>In\u017cynieria elektryczna<\/h4>\n                        <\/div>\n                        <div class=\"bottom\">\n                            <div class=\"image-container\"><img decoding=\"async\" width=\"1000\" height=\"1500\" src=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/service-electrical-engineering.jpg\" class=\"attachment-large size-large wp-post-image\" alt=\"\" srcset=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/service-electrical-engineering.jpg 1000w, https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/service-electrical-engineering-200x300.jpg 200w, https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/service-electrical-engineering-768x1152.jpg 768w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/div>\n                            <div class=\"arrow\">\n                                <a href=\"https:\/\/contec-ias.com\/pl\/us\u0142uga\/inzynieria-elektryczna\/\">\n                                    <svg width=\"21\" height=\"22\" viewBox=\"0 0 21 22\" fill=\"none\"\n                                        xmlns=\"http:\/\/www.w3.org\/2000\/svg\">\n                                        <path\n                                            d=\"M7.9395 18.9395L10.0605 21.0605L20.121 11L10.0605 0.939453L7.9395 3.06045L14.379 9.49995H0V12.5H14.379L7.9395 18.9395Z\"\n                                            fill=\"currentColor\" \/>\n                                    <\/svg>\n                                <\/a>\n                            <\/div>\n                        <\/div>\n                        <a href=\"https:\/\/contec-ias.com\/pl\/us\u0142uga\/inzynieria-elektryczna\/\" class=\"full-link\"><\/a>\n                    <\/div>\n                            <\/div>\n            <\/div>\n<\/section>\n\n<section  class=\"we-featured_cases\">\n    <div class=\"inner-content\">\n        \n        <div class=\"the-content\" data-aos=\"fade-up\">\n            <h2><span style=\"font-weight: 400;\">Powi\u0105zane przypadki<\/span><\/h2>\n        <\/div>\n                    <div class=\"cases-container\">\n                                                        <div class=\"case-item\" data-aos=\"fade-up\" data-aos-delay=\"0\">\n                        <div class=\"image-container\">\n                            <img decoding=\"async\" width=\"1500\" height=\"1000\" src=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/High-voltage-1500x1000.jpg\" class=\"attachment-large size-large wp-post-image\" alt=\"\" srcset=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/High-voltage-1500x1000.jpg 1500w, https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/High-voltage-300x200.jpg 300w, https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/High-voltage-768x512.jpg 768w, https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/High-voltage-1536x1024.jpg 1536w, https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/High-voltage-2048x1365.jpg 2048w\" sizes=\"(max-width: 1500px) 100vw, 1500px\" \/>                        <\/div>\n                        <div class=\"info\">\n                            <div class=\"arrow\">\n                                <a href=\"https:\/\/contec-ias.com\/pl\/przypadek\/zwiekszenie-bezpieczenstwa-elektrycznego-dzieki-globalnej-zasadzie-uziemienia\/\">\n                                    <svg width=\"14\" height=\"14\" viewBox=\"0 0 14 14\" fill=\"none\"\n                                        xmlns=\"http:\/\/www.w3.org\/2000\/svg\">\n                                        <path\n                                            d=\"M5.293 12.293L6.707 13.707L13.414 6.99997L6.707 0.292969L5.293 1.70697L9.586 5.99997H0V7.99997H9.586L5.293 12.293Z\"\n                                            fill=\"currentColor\" \/>\n                                    <\/svg>\n\n                                <\/a>\n                            <\/div>\n                            <h4>Zwi\u0119kszenie bezpiecze\u0144stwa elektrycznego dzi\u0119ki globalnej zasadzie uziemienia<\/h4>\n                        <\/div>\n                        <a href=\"https:\/\/contec-ias.com\/pl\/przypadek\/zwiekszenie-bezpieczenstwa-elektrycznego-dzieki-globalnej-zasadzie-uziemienia\/\" class=\"full-link\"><\/a>\n                    <\/div>\n                                                        <div class=\"case-item\" data-aos=\"fade-up\" data-aos-delay=\"50\">\n                        <div class=\"image-container\">\n                            <img decoding=\"async\" width=\"1500\" height=\"998\" src=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/cases-archive.jpg\" class=\"attachment-large size-large wp-post-image\" alt=\"\" srcset=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/cases-archive.jpg 1500w, https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/cases-archive-300x200.jpg 300w, https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/cases-archive-768x511.jpg 768w\" sizes=\"(max-width: 1500px) 100vw, 1500px\" \/>                        <\/div>\n                        <div class=\"info\">\n                            <div class=\"arrow\">\n                                <a href=\"https:\/\/contec-ias.com\/pl\/przypadek\/nowy-park-tankowania\/\">\n                                    <svg width=\"14\" height=\"14\" viewBox=\"0 0 14 14\" fill=\"none\"\n                                        xmlns=\"http:\/\/www.w3.org\/2000\/svg\">\n                                        <path\n                                            d=\"M5.293 12.293L6.707 13.707L13.414 6.99997L6.707 0.292969L5.293 1.70697L9.586 5.99997H0V7.99997H9.586L5.293 12.293Z\"\n                                            fill=\"currentColor\" \/>\n                                    <\/svg>\n\n                                <\/a>\n                            <\/div>\n                            <h4>Dostarczanie system\u00f3w elektrycznych i automatyki do bezpiecznej obs\u0142ugi kwas\u00f3w<\/h4>\n                        <\/div>\n                        <a href=\"https:\/\/contec-ias.com\/pl\/przypadek\/nowy-park-tankowania\/\" class=\"full-link\"><\/a>\n                    <\/div>\n                                                        <div class=\"case-item\" data-aos=\"fade-up\" data-aos-delay=\"100\">\n                        <div class=\"image-container\">\n                            <img decoding=\"async\" width=\"1000\" height=\"1500\" src=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/service-electrical-engineering.jpg\" class=\"attachment-large size-large wp-post-image\" alt=\"\" srcset=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/service-electrical-engineering.jpg 1000w, https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/service-electrical-engineering-200x300.jpg 200w, https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/03\/service-electrical-engineering-768x1152.jpg 768w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/>                        <\/div>\n                        <div class=\"info\">\n                            <div class=\"arrow\">\n                                <a href=\"https:\/\/contec-ias.com\/pl\/przypadek\/zwiekszenie-zdolnosci-przylaczeniowej-sieci-dystrybucyjnej\/\">\n                                    <svg width=\"14\" height=\"14\" viewBox=\"0 0 14 14\" fill=\"none\"\n                                        xmlns=\"http:\/\/www.w3.org\/2000\/svg\">\n                                        <path\n                                            d=\"M5.293 12.293L6.707 13.707L13.414 6.99997L6.707 0.292969L5.293 1.70697L9.586 5.99997H0V7.99997H9.586L5.293 12.293Z\"\n                                            fill=\"currentColor\" \/>\n                                    <\/svg>\n\n                                <\/a>\n                            <\/div>\n                            <h4>Zwi\u0119kszenie zdolno\u015bci przy\u0142\u0105czeniowej sieci dystrybucyjnej<\/h4>\n                        <\/div>\n                        <a href=\"https:\/\/contec-ias.com\/pl\/przypadek\/zwiekszenie-zdolnosci-przylaczeniowej-sieci-dystrybucyjnej\/\" class=\"full-link\"><\/a>\n                    <\/div>\n                            <\/div>\n            <\/div>\n<\/section>\n","protected":false},"excerpt":{"rendered":"","protected":false},"featured_media":3443,"menu_order":134,"template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-3691","case","type-case","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Modernizacja podstacji WN\/SN w rafinerii ropy naftowej - Contec<\/title>\n<meta name=\"description\" content=\"Nasza wiedza techniczna i wykonanie zapewni\u0142y klientowi korzy\u015bci z bezpiecznej i niezawodnej instalacji WN\/SN. Czytaj wi\u0119cej!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/contec-ias.com\/pl\/przypadek\/modernizacja-podstacji-wn-sn-w-rafinerii-ropy-naftowej\/\" \/>\n<meta property=\"og:locale\" content=\"pl_PL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Modernizacja podstacji WN\/SN w rafinerii ropy naftowej - Contec\" \/>\n<meta property=\"og:description\" content=\"Nasza wiedza techniczna i wykonanie zapewni\u0142y klientowi korzy\u015bci z bezpiecznej i niezawodnej instalacji WN\/SN. Czytaj wi\u0119cej!\" \/>\n<meta property=\"og:url\" content=\"https:\/\/contec-ias.com\/pl\/przypadek\/modernizacja-podstacji-wn-sn-w-rafinerii-ropy-naftowej\/\" \/>\n<meta property=\"og:site_name\" content=\"Contec\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-28T11:22:14+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/04\/oil-and-gas.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"706\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/contec-ias.com\\\/pl\\\/przypadek\\\/modernizacja-podstacji-wn-sn-w-rafinerii-ropy-naftowej\\\/\",\"url\":\"https:\\\/\\\/contec-ias.com\\\/pl\\\/przypadek\\\/modernizacja-podstacji-wn-sn-w-rafinerii-ropy-naftowej\\\/\",\"name\":\"Modernizacja podstacji WN\\\/SN w rafinerii ropy naftowej - Contec\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/contec-ias.com\\\/pl\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/contec-ias.com\\\/pl\\\/przypadek\\\/modernizacja-podstacji-wn-sn-w-rafinerii-ropy-naftowej\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/contec-ias.com\\\/pl\\\/przypadek\\\/modernizacja-podstacji-wn-sn-w-rafinerii-ropy-naftowej\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/contec-ias.com\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/oil-and-gas.png\",\"datePublished\":\"2026-01-06T19:07:17+00:00\",\"dateModified\":\"2026-04-28T11:22:14+00:00\",\"description\":\"Nasza wiedza techniczna i wykonanie zapewni\u0142y klientowi korzy\u015bci z bezpiecznej i niezawodnej instalacji WN\\\/SN. Czytaj wi\u0119cej!\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/contec-ias.com\\\/pl\\\/przypadek\\\/modernizacja-podstacji-wn-sn-w-rafinerii-ropy-naftowej\\\/#breadcrumb\"},\"inLanguage\":\"pl-PL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/contec-ias.com\\\/pl\\\/przypadek\\\/modernizacja-podstacji-wn-sn-w-rafinerii-ropy-naftowej\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\\\/\\\/contec-ias.com\\\/pl\\\/przypadek\\\/modernizacja-podstacji-wn-sn-w-rafinerii-ropy-naftowej\\\/#primaryimage\",\"url\":\"https:\\\/\\\/contec-ias.com\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/oil-and-gas.png\",\"contentUrl\":\"https:\\\/\\\/contec-ias.com\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/oil-and-gas.png\",\"width\":1200,\"height\":706,\"caption\":\"oil and gas\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/contec-ias.com\\\/pl\\\/przypadek\\\/modernizacja-podstacji-wn-sn-w-rafinerii-ropy-naftowej\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Strona g\u0142\u00f3wna\",\"item\":\"https:\\\/\\\/contec-ias.com\\\/pl\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Realizacje\",\"item\":\"https:\\\/\\\/contec-ias.com\\\/pl\\\/cases\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Modernizacja podstacji WN\\\/SN w rafinerii ropy naftowej\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/contec-ias.com\\\/pl\\\/#website\",\"url\":\"https:\\\/\\\/contec-ias.com\\\/pl\\\/\",\"name\":\"Contec\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/contec-ias.com\\\/pl\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pl-PL\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Modernizacja podstacji WN\/SN w rafinerii ropy naftowej - Contec","description":"Nasza wiedza techniczna i wykonanie zapewni\u0142y klientowi korzy\u015bci z bezpiecznej i niezawodnej instalacji WN\/SN. Czytaj wi\u0119cej!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/contec-ias.com\/pl\/przypadek\/modernizacja-podstacji-wn-sn-w-rafinerii-ropy-naftowej\/","og_locale":"pl_PL","og_type":"article","og_title":"Modernizacja podstacji WN\/SN w rafinerii ropy naftowej - Contec","og_description":"Nasza wiedza techniczna i wykonanie zapewni\u0142y klientowi korzy\u015bci z bezpiecznej i niezawodnej instalacji WN\/SN. Czytaj wi\u0119cej!","og_url":"https:\/\/contec-ias.com\/pl\/przypadek\/modernizacja-podstacji-wn-sn-w-rafinerii-ropy-naftowej\/","og_site_name":"Contec","article_modified_time":"2026-04-28T11:22:14+00:00","og_image":[{"width":1200,"height":706,"url":"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/04\/oil-and-gas.png","type":"image\/png"}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/contec-ias.com\/pl\/przypadek\/modernizacja-podstacji-wn-sn-w-rafinerii-ropy-naftowej\/","url":"https:\/\/contec-ias.com\/pl\/przypadek\/modernizacja-podstacji-wn-sn-w-rafinerii-ropy-naftowej\/","name":"Modernizacja podstacji WN\/SN w rafinerii ropy naftowej - Contec","isPartOf":{"@id":"https:\/\/contec-ias.com\/pl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/contec-ias.com\/pl\/przypadek\/modernizacja-podstacji-wn-sn-w-rafinerii-ropy-naftowej\/#primaryimage"},"image":{"@id":"https:\/\/contec-ias.com\/pl\/przypadek\/modernizacja-podstacji-wn-sn-w-rafinerii-ropy-naftowej\/#primaryimage"},"thumbnailUrl":"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/04\/oil-and-gas.png","datePublished":"2026-01-06T19:07:17+00:00","dateModified":"2026-04-28T11:22:14+00:00","description":"Nasza wiedza techniczna i wykonanie zapewni\u0142y klientowi korzy\u015bci z bezpiecznej i niezawodnej instalacji WN\/SN. Czytaj wi\u0119cej!","breadcrumb":{"@id":"https:\/\/contec-ias.com\/pl\/przypadek\/modernizacja-podstacji-wn-sn-w-rafinerii-ropy-naftowej\/#breadcrumb"},"inLanguage":"pl-PL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/contec-ias.com\/pl\/przypadek\/modernizacja-podstacji-wn-sn-w-rafinerii-ropy-naftowej\/"]}]},{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/contec-ias.com\/pl\/przypadek\/modernizacja-podstacji-wn-sn-w-rafinerii-ropy-naftowej\/#primaryimage","url":"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/04\/oil-and-gas.png","contentUrl":"https:\/\/contec-ias.com\/wp-content\/uploads\/2025\/04\/oil-and-gas.png","width":1200,"height":706,"caption":"oil and gas"},{"@type":"BreadcrumbList","@id":"https:\/\/contec-ias.com\/pl\/przypadek\/modernizacja-podstacji-wn-sn-w-rafinerii-ropy-naftowej\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Strona g\u0142\u00f3wna","item":"https:\/\/contec-ias.com\/pl\/"},{"@type":"ListItem","position":2,"name":"Realizacje","item":"https:\/\/contec-ias.com\/pl\/cases\/"},{"@type":"ListItem","position":3,"name":"Modernizacja podstacji WN\/SN w rafinerii ropy naftowej"}]},{"@type":"WebSite","@id":"https:\/\/contec-ias.com\/pl\/#website","url":"https:\/\/contec-ias.com\/pl\/","name":"Contec","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/contec-ias.com\/pl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pl-PL"}]}},"_links":{"self":[{"href":"https:\/\/contec-ias.com\/pl\/wp-json\/wp\/v2\/case\/3691","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/contec-ias.com\/pl\/wp-json\/wp\/v2\/case"}],"about":[{"href":"https:\/\/contec-ias.com\/pl\/wp-json\/wp\/v2\/types\/case"}],"version-history":[{"count":1,"href":"https:\/\/contec-ias.com\/pl\/wp-json\/wp\/v2\/case\/3691\/revisions"}],"predecessor-version":[{"id":3692,"href":"https:\/\/contec-ias.com\/pl\/wp-json\/wp\/v2\/case\/3691\/revisions\/3692"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/contec-ias.com\/pl\/wp-json\/wp\/v2\/media\/3443"}],"wp:attachment":[{"href":"https:\/\/contec-ias.com\/pl\/wp-json\/wp\/v2\/media?parent=3691"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}